( Brand: Licor ), ( Manufacturer Part Number: LI-185R ), ( Part Type: Adapter Sensor )
The LI-COR LI-185R and LI-185B Quantum/Radiometer/Photometer are versatile and high-performing instruments designed for measuring photosynthesis and irradiance in research, agriculture, and environmental applications. These instruments are manufactured by LI-COR Biosciences, a leading company known for producing innovative and precise scientific equipment.
The LI-185R and LI-185B Quantum/Radiometer/Photometer come with a spherical adapter sensor, specifically the I-193SB model. This sensor is designed to provide accurate and uniform measurements of photosynthetically active radiation (PAR) across a wide range of angles and distances. The I-193SB sensor is equipped with a high-efficiency, high-sensitivity silicon photodiode that ensures accurate and reliable measurements of incident PAR.
The LI-185R and LI-185B instruments offer several advanced features, including a high measurement resolution of 0.1 mol m-2 s-1, a measurement range of 0 to 10,000 mol m-2 s-1, and a response time of less than 1 ms. These features enable precise and timely measurements of photosynthetic activity and irradiance, which are essential for understanding plant growth and response to various environmental conditions.
The LI-185R and LI-185B Quantum/Radiometer/Photometer also offer several connectivity options, including a USB interface and a RS-232 serial interface, which allow for easy data transfer and integration with other data logging and control systems. The instruments also come with LI-COR's proprietary software, LI-COR WinDAS, which provides advanced data analysis and visualization capabilities.
The LI-COR LI-185R and LI-185B Quantum/Radiometer/Photometer are designed for durability and ease of use. They feature a rugged, waterproof design, making them suitable for use in various environmental conditions. The instruments also come with a rechargeable battery, which provides up to 12 hours of continuous operation.
In summary, the LI-COR LI-185R and LI-185B Quantum/Radiometer/Photometer, along with the I-193SB spherical adapter sensor, offer precise and accurate measurements of photosynthetic activity and irradiance, making them essential tools for researchers, farmers, and environmental scientists. Their advanced features, versatility, and durability make them an excellent investment for anyone seeking to gain a deeper understanding of plant growth and response to environmental conditions.
The LICOR LI-185R and LI-COR LI-185B are infrared gas analyzers used for measuring CO2, H2O, and CH4 concentrations in the atmosphere or other gases. The I-193SB spherical adapter sensor is designed for use with these models, enabling the measurement of gases in a broader range of applications.
2. Pros of buying LICOR LI-185R, LI-COR LI-185B, and I-193SB:a. High Accuracy: These instruments offer high accuracy and precision, making them ideal for research applications and industrial processes where precise gas concentration measurements are essential.
b. Versatility: The LI-185R and LI-185B can be used in various applications, including environmental monitoring, greenhouse gas management, and process control. The I-193SB spherical adapter sensor expands their versatility by enabling measurements in more complex environments.
c. User-friendly: The instruments have user-friendly interfaces, making operation straightforward for users of all skill levels.
d. Wide Dynamic Range: These analyzers have a wide dynamic range, allowing them to measure gas concentrations from very low to very high levels.
e. Robust Design: The LICOR LI-185R, LI-COR LI-185B, and I-193SB are built to withstand harsh environments, ensuring reliable operation even in challenging conditions.
3. Cons of buying LICOR LI-185R, LI-COR LI-185B, and I-193SB:a. High Cost: These instruments and the I-193SB spherical adapter sensor can be quite expensive, making them a significant investment for many users.
b. Complex Setup: While the instruments themselves are user-friendly, setting them up and integrating them into larger systems can be a complex process that requires specialized knowledge and expertise.
c. Limited Compatibility: The LI-185R and LI-185B are specifically designed for use with the I-193SB spherical adapter sensor. They may not be compatible with other sensors or instruments, limiting their flexibility in some applications.
4. Conclusion:The LICOR LI-185R, LI-COR LI-185B, and I-193SB spherical adapter sensor are powerful tools for measuring gas concentrations in various applications. Their high accuracy, versatility, and robust design make them valuable assets for researchers and industrial users. However, their high cost and complex setup may make them a challenging investment for some. Ultimately, the decision to purchase these instruments depends on the specific needs and resources of the user.
5. Recommendation:If you require high-accuracy gas concentration measurements for research or industrial applications and have the necessary budget and expertise for setup and integration, the LICOR LI-185R, LI-COR LI-185B, and I-193SB spherical adapter sensor are excellent choices. However, if you have limited resources or require more flexibility in your gas measurement system, you may want to consider alternative, more affordable options.
Cool!, Perfect for areas with moving or inconsistent light. This device measures PAR Integrated from 306 around the sensor. Fresh batteries. We made a simple cable that is not included, but waterproof and other cables are easily bought or built.
Up for sale is a light sensing system consisting of Li-Cor LI-185B Quantum/Radiometer/Photometer, I-193SB Spherical Quantum Sensor Adapter SPQA in the serial number means an underwater model. Watch the video of this system measuring light from a moving source.