( Brand: Solarmeter ), ( Manufacturer Part Number: MODEL5 ), ( Part Type: Uv Meter ), ( Modified Item: No ), ( Country/region Of Manufacture: United States ), ( Measurement Range: 0-199.9 Mw/cm2 Total Uv, 260 To 400nm ), ( Accuracy: 5 Ref.nist )
The Model 5 Solarmeter UV Meter 260 is a sophisticated and advanced tool designed for measuring ultraviolet (UV) radiation across a broad spectrum. This UV meter, specifically model 5.0, covers the range of 260 to 400 nanometers (nm), making it an ideal choice for various applications where UV radiation analysis is crucial.
The device features a high-quality, liquid crystal display (LCD) that provides clear and accurate readings. It is equipped with a built-in data logger, which allows users to store up to 1,000 readings for later analysis. The data logger has a user-friendly interface, allowing easy navigation and data retrieval.
The Model 5 Solarmeter UV Meter 260 is also designed for durability and portability. It is compact and lightweight, making it easy to carry around for field measurements. The device is water-resistant, ensuring protection against accidental splashes or rain.
This UV meter is highly sensitive and offers a high measurement accuracy of 2%. It is suitable for measuring UV radiation levels in various environments, including solar energy applications, photobiology, dermatology, and quality control in the manufacturing industry.
Moreover, the Model 5 Solarmeter UV Meter 260 comes with a calibration certificate, ensuring that the device is accurate and reliable. It is powered by two AAA batteries, which provide a long operating time.
In summary, the Model 5 Solarmeter UV Meter 260 is a versatile and reliable tool for measuring UV radiation. Its wide measurement range, high accuracy, and built-in data logger make it an excellent choice for researchers, engineers, and professionals in various fields.
Pros of buying a Model 5 Solarmeter UV Meter 5.0 (260-400nm):1. Accurate Measurements: This UV meter is known for its high accuracy, measuring UV-A and UV-B radiation with a 2% error.
2. Wide Detection Range: It can detect UV radiation in the range of 260-400nm, which is essential for various applications including photobiology, photochemistry, and UV curing.
3. Portable and Durable: The Model 5 Solarmeter is compact and lightweight, making it easy to carry around. It is also built to withstand harsh environments.
4. Auto-Shutoff Feature: This feature helps to save battery life and prevents accidental damage.
5. Data Logging: The device has a data logging function that allows you to save up to 10,000 readings.
Cons of buying a Model 5 Solarmeter UV Meter 5.0 (260-400nm):1. Price: The device is somewhat expensive compared to other UV meters in the market.
2. Lack of Real-Time Display: The data is only displayed after a measurement, which might not be suitable for real-time monitoring.
3. Unnecessary Features: Some users might find the data logging feature unnecessary, as it might add to the complexity of the device.
Recommendation:The Model 5 Solarmeter UV Meter 5.0 (260-400nm) is a reliable and accurate UV meter. While it might be expensive, its high accuracy and wide detection range make it a valuable investment for professionals in fields such as photobiology, photochemistry, and UV curing. For casual users or those on a tight budget, there might be cheaper alternatives with similar functionality, but the Model 5 Solarmeter offers a level of precision and durability that is hard to match. Therefore, if you need a high-quality UV meter for your professional or personal use, the Model 5 Solarmeter is a good choice.
Take overall reading at of tanning bed bench pointing up with canopy closed, or check individual lamps acrylic. If unsure of what original new values were, replace two adjacent lamps with ones the same kind and compare old. For urethral rays use model 7. Proper usage of Solarmeter ultraviolet radiometer for lamp aging test swear eye protection when checking uv lamps uv-block wrap around glasses allow to warm-up prior taking readings at least 5 min.
Operation to operate your Solarmeter, aim the sensor window located on top panel of meter directly at a uv source. For outdoor high intensity applications sensor the semiconductor uv sensor consists of a gasp photo diode chip and filter which is completely insensitive to visible light longer than 400 nm infrared radiation, since its spectral response covers only the region from 260. 5v, the numbers on LCD display will begin to dim, indicating need for battery replacement. Readings on a chart.
Standard Iva b meter features:compact, handheld, and durable simple single-button operations traceable display made in supplications:monitoring uv lamp intensity aging testing acrylic shield transmission monitoring Suva therapy aging measuring outdoor uv choose model 5. UV meter is better for this purpose. Keep track of hours vs. Press and hold the push-button switch on face of meter.
For best results take note of the distance reading was taken from uv source in order to ensure repeatable. Battery operation voltage is viable from 9v down to 6. Med hr meter to relate te time. When checking acrylic transmission, take reading through then remove and hold meter sensor at approximately the same distance from lamp as shield was located.
Applications include solar uv detection as the spectral response is well matched to spectrum and tanning lamps peaking near 365 nm new era fluorescent high pressure hid. When checking aging of lamps, keep measuring distance and locations constant. Keep sensor free of oil, dirt, etc. Lamps should be replaced when output drops to about 70 of their original new readings.
Use a dry, soft cloth to clean the instrument. Do not subject the meter to extremes in temperature, humidity, shock or dust. Note: model 6. When using this meter to compare different types of lamps, due their spectral power distributions, the readings should be considered relative rather than absolute.
Under typical service load, a standard 9v battery will last approximately 2 years. Although higher output lamps of similar spuds will read than low lamps, ones that peak near 365 nm as does the meter response peaking 350 even if total uv both is same. This meter is primarily seeing the Iva browning rays.